Japanese
Title経食道心エコー法による心臓手術中の冠血流の評価 ―イソフルランを用いて―
Subtitle原著
Authors伊東浩司*, 工藤治彦*, 吉良慎一郎*, 水谷明男*, 吉武重徳*, 岩坂日出男*, 野口隆之**, 谷口一男***
Authors(kana)
Organization*大分医科大学麻酔学教室, **大分医科大学集中治療部, ***大分医科大学手術部
Journal循環制御
Volume18
Number1
Page40-44
Year/Month1997/
Article原著
Publisher日本循環制御医学会
Abstract「要旨」経食道心エコー法を用いて心臓手術中の冠血流速評価を試みた. 弁置換等の非冠動脈手術症例7人(以下非冠動脈群)と冠動脈バイパスグラフト手術症例9人(以下冠動脈群)に分類して, イソフルラン濃度を0, 1, 2%と変化させたときの左冠動脈主幹部LMTの冠血流速を測定した. 血行動態値は, イソフルラン0%のときに比べて, 1%および2%のときの両群の血圧および2%のときの冠動脈群の全身血管抵抗が有意に低下した. 冠血流速は, イソフルラン濃度上昇に伴い, 非冠動脈群で上昇する傾向にあった. 群内比較では冠動脈群の拡張期で0%と2%値(0.76±0.20 VS 1.18±0.29 m・sec-1)のみ有意差があった. 群間比較では有意差はなかったがイソフルラン各濃度において冠動脈群は非冠動脈群と比べ拡張期は速く, 収縮期は遅い傾向にあった.
Practice基礎医学・関連科学
KeywordsTransesophageal echocardiography, Coronary blood flow velocity, Isoflurane, Cardiac surgery, Coronary disease
English
TitleEvaluation of Coronary Blood Flow with Transesophageal Echocardiography in Response to Inhaled Isoflurane in Cardiac Surgery
Subtitle
AuthorsKoji Ito*, Haruhiko Kudo*, Shinichiro Kira*, Akio Myzutani*, Shigenori Yoshitake*, Hideo Iwasaka*, Takayuki Noguchi**, Kazuo Taniguchi***
Authors(kana)
Organization*Departments of Anesthesiology, Oita Medical University, **Intensive Care Medicine, Oita Medical University, ***Surgical Clinic, Oita Medical University
JournalCirculation Control
Volume18
Number1
Page40-44
Year/Month1997/
ArticleOriginal article
PublisherJapan Society of Circulation Control
AbstractCoronary artery (left main trunc) blood flow velocity (CBFV) changes were measured with transesophageal echocardiography in response to inhaled isoflurane at the concentrations of 0%, 1% and 2%, in 7 non-coronary cardiac surgery patients (non coronary group) and in 9 coronary bypass graft surgery patients (coronary goup). Anesthesia was maintained with high dose fentanyl, diazepam and pancuronium, and isoflurane was additionally inhaled during CBFV measurements. Systemic blood pressure decreased significantly in both groups and systemic vascular resistance index decreased significantly at 2 % isoflurane inhalation in the coronary group. CBFV changes in the non coronary group in response to inhaled isoflurane were not significant. Both systolic and diastolic CBFV increased in the non coronary group as the isoflurane concentration increased, however, no significance was observed. In coronary group, 2 % isoflurane inhalation significantly increased diastolic CBFV compared to the non inhaled patients (0.76±0.20 vs 1.18±0.29 m/sec). Although no significanct difference in CBFV was seen between both groups, CBFV in the coronary group was faster at diastolic state and slower at systolic state than those of non coronary group. (Circ Cont 18:40〜44, 1997)
PracticeBasic medicine
KeywordsTransesophageal echocardiography, Coronary blood flow velocity, Isoflurane, Cardiac surgery, Coronary disease

【全文PDF】